Applications
Steam heated vaporizers are used in petrochemical and cryogenic plants to vaporize liquefied gases such as:
Oxygen
Nitrogen
Argon
Ethylene
Propylene
Natural Gas
In a load range from approx. 500 Nm³/h up to 195 000 Nm³/h.
Characteristics
Linde´s steam heated water bath vaporizer is a robust and
reliable solution with a large range capacity. The unit consists of
a round water vessel with an overflow nozzle in which a coiled
tube bundle is submerged.
The characteristics of Linde Steam Heated Water Bath
Vaporizers are:
![]() |
The water is heated up by direct steam injection The steam flow is controlled by water temperature controllers During stand-by conditions, the water temperature is kept through a small steam lance at 60 °C The water circulation is achieved by means of |
Schalchen Plant Germany