Applications and Characteristics

Applications

Steam heated vaporizers are used in petrochemical and cryogenic plants to vaporize liquefied gases such as:

Oxygen

Nitrogen

Argon

Ethylene

Propylene

Natural Gas

In a load range from approx. 500 Nm³/h up to 195 000 Nm³/h.

Characteristics

Linde´s steam heated water bath vaporizer is a robust and reliable solution with a large range capacity. The unit consists of a round water vessel with an overflow nozzle in which a coiled tube bundle is submerged.

The characteristics of Linde Steam Heated Water Bath Vaporizers are:

 

The water is heated up by direct steam injection
through one or more steam lances, in such a way that
steam hammering is avoided

The steam flow is controlled by water temperature controllers

During stand-by conditions, the water temperature is kept through a small steam lance at 60 °C

The water circulation is achieved by means of
buoyancy and gravitiy, so that availability from 0 to
full capacity can be reached within two minutes

 


In case an immediate availability within 10 seconds is required, additional water circulating pumps can be installed.
DeutschRussian Sitemap Contact Schalchen Plant Germany